The PHCC Pro Series PS-C22 Combination Backup and Primary Sump Pump System comes pre-assembled with check valves installed, weep holes drilled, and is plumbed and mounted on a platform for quick and easy installation. The energy efficient primary AC sump pump will provide 2,770 GPH (46.2 GPM) at a 10 ft. lift and its caged dual float (DFC1.5) will deliver years of dependable service. The backup sump pump will protect from power outages, primary AC sump pump failure, primary AC float failure and provide extra capacity if needed. Plus, when maintenance is needed or a problem arises, it sounds an alarm, pinpoints problems, provides solutions on the control panel, and (using one of the Pro Series Connect Modules) can alert remotely via, text, email or in app notification. The backup system delivers 1,850 GPH (30.8 GPM) of pumping capacity at a 10 foot lift and will pump intermittently for days on a single charge of the Pro Series battery.|Pre-assembled Pro Series ST1033 sump pump, enhanced dual float switch and a Pro Series 1850 backup sump pump system|AC primary sump pump capacity: 2,770 GPH (46 GPM) at 10 ft. lift|Backup sump pump capacity: 1,850 GPH (30.8 GPM) at 10 ft. lift|2 sets of dual float switches for 4 times the protection|Backup system monitoring controller detects irregularities, sounds an alarm, pinpoints problems and solutions on the control panel|Alerts if AC power is out or the circuit breaker has tripped|Monitors the battery and alarms if maintenance or replacement is needed|USB data port and remote terminals connect to external devices such as a Pro Series connect module, home automation systems or other devices for remote notification|Backup pump will assist primary pump if excessive amounts of water are entering the sump pit|Battery backup system pumps intermittently for days on a single charge|Automatically switches to battery power when AC fails|1.6 Amp charger automatically recharges and maintains the battery|Designed for use with maintenance or maintenance free batteries|Fluid sensor will monitor the water level of a Pro Series wet cell battery (B2200 or B1000)|Warning alarms can be temporarily silenced during a power outage|Both primary and backup pump run weekly tests to exercise and check for proper operation|Includes: backup pump, monitoring control box with dual float switch and fluid sensor, charger, battery box, primary AC pump, enhanced dual float controller with caged dual float (DFC1.5), and two check valves pre-assembles on a sump foot
short description:
PRO SERIES PAIR OF PUMPS